Motion Pro Digital Tire Gauge P/N 08-0468

Quick Use Instructions

Press the

ON/OFF button to power-up gauge. The gauge will display current pressure,

pressure unit (Psi, Kpa, etc…) and battery condition indicator. Select the desired pressure

unit by pressing the

FUNCTION button until the desired pressure is shown at the bottom

of the display. Choices are Psi, Kpa, Bar and Kgf/cm2 (Note: pressure unit cannot be

changed when gauge is in

hold mode. See below for details on the hold setting.)

The gauge is now ready to measure pressure. Connect the gauge to the tire valve,

the display will show the current tire pressure to the tenth (1/10) of a pound. You

may depress the chrome pressure release button on the front of the blue trapezoid

body to release excess pressure from the tire until you reach your desired pressure.

The gauge will continuously monitor the current pressure unless set to

hold mode

(see below). After use of the gauge is complete it can either be turned off manually

to preserve maximum battery life or allowed to turn off automatically after the

programmed auto-off time has elapsed (see below for instructions on changing the

auto-off timer).

The backlight will shut down after 20 seconds to preserve battery life. The backlight can

be relit by pressing the

FUNCTION button.

The gauge will automatically recalibrate for changes in temperature or ambient pressure

during use; however, the gauge can be manually recalibrated anytime using the Manual

Recalibration procedure described below if desired.

Note: The gauge will not hold pressure once removed from the tire valve. However, if it is

desired that the gauge does retain pressure, it can be set to hold mode and the maximum

pressure will be retained on the display until gauge is turned off or is allowed to auto-off.

Additional Features

Manual Recalibration

With the unit turned “on” and

0.0 displayed, press and hold the FUNCTION button for 5 seconds

until

- - 0 – appears. Release the FUNCTION button and -000 will be displayed. Immediately press

the ON/OFF button and

0000 will display, then flash, –End will momentarily be displayed, and the

gauge display will return to

0.0. The recalibration process is now complete and the gauge is once

again ready for use.

Setting Cont and hold Functions

Note: Virtually all users will normally use the

Cont (Continuous) mode for normal tire pressure readings

allowing the gauge to continuously monitor the current pressure; however,

hold mode may be desirable

in certain applications where the maximum pressure reading will be retained on the display until gauge

is turned off or is allowed to auto-off.

With the unit turned “on” and 0.0 displayed, press and hold the

FUNCTION button for 5 seconds until

- - 1 – appears. Release the FUNCTION button. Cont and hold will alternately be displayed. Press the

ON/OFF button when the desired mode is displayed. The selected mode will then flash,

–End will momentarily

be displayed, and the gauge display will return to

0.0. The gauge is now ready for use.

Note: HOLD will be displayed at the base of the display when in hold mode. That area of the display will be blank

when in

Cont (continuous) mode.

OVER -

I08-0468

6/2013

INSTRUCTIONS

Process Black

White

White/Black MOTION PRO, INC. LOGO

Motion Pro, Inc.

867 American Street

San, Carlos, CA 94070

Tel: 650.594.9600 Fax: 650.594.9610

www.motionpro.com

Advertising