6. UC5 System Maintenance

6.1. Daily Maintenance:

 Grease the friction pads on the sprayer boom.
 Ensure there is a clean and dry foam inserted into each sensor.

6.2. Cleaning Ultrasonic Height Sensors:

 Remove the foam disc from the sensor and wash it with clean water. Squeeze out water and

allow the foam disc to dry.

 If the transducer inside the sensor is also dirty, wash it using clean water. Do not submerge or

pressure-wash the sensor.

 Chemicals or compressed air should never be used.
 The sensor can be used if it is wet, however a valid height reading may not be obtained until it is

completely dry.