3.1. Setting Control Options
3.1.1. Sensitivity:
The Sensitivity can be adjusted from 1 to 10, with 5 being the default setting. A lower number will reduce
the system sensitivity and improve stability. Higher settings will speed up the response.
3.1.2. Mode:
The Mode button allows the system to be changed between Soil Mode™, Crop Mode™ and Hybrid™
Mode. Soil Mode allows the sensors to read a height from the spray nozzles to the ground. Crop Mode
will read the height from the spray nozzles to the top of the crop canopy. Hybrid Mode uses a
combination of the crop and soil readings.