Pair and length measurement (PAIR & LENGTH) function:

After entering into “PAIR & LENGTH" measurement , the tester shall
have pair and length (PAIR & LENGTH) test and it will display as
follows to indicate the measurement is being undertaken:

----T e s t i n g ----
12345678...

Note:In view of different technical parameters of different brand
cables, the user should use “calibration" function before length
measurement (Refer to the details herein).

Test Result 1: Short circuit (SHORT)

It will display as follows if there is any short circuit in cable or terminal:
(12 short circuit in the sample)

Short:
12

(The tester is incapable to exactly locate short circuit.)
At the moment, push key to restart test or push key to return
the main menu.
Always correct short circuit error first and then start further
measurement.

Test Result 2: Normal pair and length (PAIR &LENGTH) display

P a i r 12 100.0m

P a i r 78 99.8m

P a i r 36 100.3m
P a i r 45 100.2m

At the moment, push key to restart test or push key to return
the main menu.

It will display as follows if pair and length(PAIR & LENGTH)
measurement is in normal condition:

PAIR&L

PAIR&L