NOYAFA NF-8108 User Manual

Page 6

Advertising
background image

(5).

(6).

(7).

(8).

(9).

(10).

Ambient temperature in work

-10℃~+60℃

Tester Ports

Tester RJ45 master port (M), tester LOOPBACK RJ45

port (L), Remote identifier RJ45 port ®

Length Measurement of Twin Twisted Cable

Scope: 1~305 M ( 3 ~1000 ft)

Calibration accuracy: 3% (+/- 0.5M or +/- 1.5 ft) (calibrating

cable > 10 M)

Shipment accuracy: 5% (+/- 0.5 M or +/- 1.5 ft). (AMP,

AT&T Class 5 cable)

Display: M or ft.

Length Calibration:

User can calibrate cable length by himself with a given

length cable. The length of calibrating cable is more

than 10 M.

Wire Sequence and Locating Cable Error:

Check errors such as open, short , reverse connection.

Automatic Time-delay Shut Off Time:

The tester does not operate for 30 minutes.

Your excellent helper in cable test!

03

Advertising