Graph Analysis Tool Graph Screen Operations

k Configuring View Window Parameters

Pressing

!3(V-Window) while the graph screen is on the display displays a View

Window function key menu along the bottom of the display.

Press the function key that corresponds to the View Window parameter you want to configure.

20070101

To exit the View Window function key menu and return to the standard function key menu,
press

J.

1(Auto)

Description

Function Key

Automatically applies the following View Window parameters.
Y-axis Elements: In accordance with screen size
X-axis Elements: In accordance with screen size when 1 data item

equals 1 dot; 1 data equals 1 dot in other cases

Resizes the graph so all of it fits in the screen along the Y-axis, without
changing the X-axis dimensions.

Specifies the unit of the numeric axis grid displayed by the Econ Axes
setting of the graph setup screen (page 3-13).
1(μ sec): microseconds

2(msec): milliseconds

3(sec): seconds

4(DHMS):days, hours, minutes, seconds (1 day, 2 hours, 30 minutes,

5 seconds = 1d2h30m5s)

5(Auto):Auto selection

Toggles display of the source data on the graph screen on and off.

2(FULL)

3(Y)

4(UNIT)

5(CHNG)

Resizes the graph so all of it fits in the screen.