PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual

Page 113

Advertising
background image

T

ESTING

AND

T

ROUBLESHOOTING

: T

EST

S

OFTWARE

0 2. 3 0 0 4. 0 3 00 . 5 4

105

4

Table 4-7: VL7/VL7U Mechanical Tests

Test Number

Test Parameter

Error Codes/Comments

000

All Stop

001

Pan

9

End Stop (Closed), 65% Speed

103

No Reset (PAN)

002

Tilt

8

End Stop (Open), 65% Speed

203

No Reset (TILT)

003

Beam

7

25% Speed

104

No Reset (PAN)

6

35% Speed

204

No Reset (TILT)

5

45% Speed

4

55% Speed

3

65% Speed

2

75% Speed

1

85% Speed

0

Full Speed

004

Lens

7

All move to front EOT, Lens 1 cycles full

travel at 100% speed

(Test Type 4D)

6

Type 4C, 33% speed

5

Type 4C, 66% speed

4

Lens 1 move to rear EOT, Lens 3

moves to front EOT, Lens 2 cycles full

travel at 100% speed (Test Type 4C)

3

Type 4B, 33% speed

2

Type 4B, 66% speed

1

All lenses move to rear EOT, Lens 3

cycles full travel at 100% speed (Test

Type 4B)

0

All synchronous at 100% speed (Test

Type 4A)

005

Intensity

9

End Stop (Closed), 65% Speed

8

End Stop (Open), 65% Speed

7

25% Speed

6

35% Speed

5

45% Speed

4

55% Speed

3

65% Speed

2

75% Speed

1

85% Speed

0

Full Speed

006

Color Plate 1

9

Plate moves to open X &Y at 100%

speed (Test Type 67D)

007

Color Plate 2

8

Type 67C, 25% speed

7

Type 67C, 50% speed

6

Type 67C, 75% speed

Advertising