PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual

Page 116

Advertising
background image

DMX512 R

EFERENCE

G

UIDE

1 0 8

02.3004.0300.54

4

Monitor Rotating Gobo Wheel Index

Sensor and Gobo Orientation Sensor

3

Monitor Color Plate 2Y sensor

2

Monitor Color Plate 2X sensor

1

Monitor Color Plate 1Y sensor

0

Monitor Color Plate 1X sensor

022/

023

Pan/Tilt

9

Display current most significant digit

(Xxxx) of the reported encoder value.

Repeatedly monitored.

8

Display current second significant digit

(xXxx) of the reported encoder value.

Repeatedly monitored.

7

Display current third significant digit

(xxXx) of the reported encoder value.

Repeatedly monitored.

6

Display current least significant digit

(xxxX) of the reported encoder value.

Repeatedly monitored.

0

Display scrolling snapshot of each digit
of the reported encoder value. Repeat-

edly monitored.

024

Form &

Function

0

Display the form and function value of

the luminaire. For the VL7, Py=F10

should be reported where y is the lumi-

naire’s port number.

Table 4-8: VL7/VL7U Default Test Programs

Test Number

Test

Functions

31

Pan and Tilt

701

Pan 25% Speed

702

Tilt 25% Speed

39

VL7 Functions

703

Beam 25% Speed

705

Edge 25% Speed

709

Rotating Gobo

506

Wheel 1 Continuous Frame

507

Wheel 2 Continuous Frame

003

Beam Test

004

Lens Test

005

Intensity Test

006

Plate 1 Test

007

Plate 2 Test

008

Fixed Gobo Test

009

Rotating Test

010

Strobe Test

Table 4-7: VL7/VL7U Mechanical Tests (Continued)

Test Number

Test Parameter

Error Codes/Comments

Advertising