Power metering – PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual
Page 31

S
YSTEM
O
PERATION
: E
QUIPMENT
P
OWER
R
EQUIREMENTS
0 2. 3 0 0 4. 0 3 00 . 5 4
23
1
Power Metering
WARNING: Power metering and connection to a house AC service should only be performed by
qualified personnel. This personnel is typically a "house electrician" supplied by the venue or other
contract electrician supplied by the venue for this purpose. This manual does not supply
procedures for metering a house AC service nor does it imply that persons using this equipment
are required to meter any type of house AC service.
Equipment
120 Volts Phase to
Neutral60 Hz Wye
Mode
208 Volts Phase to
Phase60 Hz Delta
Mode
240 Volts
Phase to Neutral
l50 Hz Wye Mode
VL2C Luminaire
11.0 amps
6.5 amps
6.3 amps
VL4 Luminaire
8.0 amps
4.8 amps
4.5 amps
Smart Repeater
9.6 amps
5.2 amps
6.0 amps
Smart Repeater Plus
12.8 amps
7.2 amps
6.5 amps
DMX200
1.0 amps
0.2 amps
0.3 amps
SPC-36 Controller
1.0 amps
0.2 amps
0.3 amps
APS6 Module (400W)
6.7 amps
3.7 amps
3.6 amps
APS6 Module (625W)
9.5 amps
5.5 amps
5.1 amps
APS6 Module (700W)
11.5 amps
5.8 amps
7.4 amps
C3 Module (1000W)
N/A
4.7 amps
4.3 amps
C3 Module (1200W)
N/A
5.2 amps
5.1 amps
DMX Power Pack
10.0 amps
6.0 amps
5.0 amps