Heater rating plate – Reznor SFT Unit Installation Manual User Manual

Page 24

Advertising
background image

Form RZ -NA-I-SFT, Mfg No. 173474 (Rev 6), Page 23

31. Heater Rating Plate

The heater rating plate is a quick reference for information about a heater and its instal-
lation requirements. In addition, the Serial No. on the rating plate identifies compo-
nents used in manufacturing that specific heater. The serial number is coded to identify
the gas valve and ignition type that was installed on the heater at the time of manufac-
ture. This information is required if service and/or replacement parts are required.

Follow the example below to decode the heater Serial No.

Example: Heater Serial No. AWH75T9N12345X

AWH

75

T9

N

12345

X

Month & Year

Safety Pilot Code Type of Type of Consecutive

Plant

of Manufacture (Type of Ignition) Valve

Gas*

Number

Designation

* N = Natural Gas; L = Propane Gas

IMPORTANT: The serial number code can only identify the original equipment. Be-
fore installing or servicing, check for a gas conversion label.

When inquiring about replacement parts, always provide the complete Model No. and
Serial No. Each heater has a "Replacement Parts Label" attached that identifies parts
specific to that heater, as well as the Model and Serial No. of the heater.

Identification of Serial No. Valve
Codes for Valves Used on Model SFT
Heaters

Code P/N

Manufacturer

*Gas

T9

147133 Robertshaw #7222DER

N

U1

147134 Robertshaw #7222DERLP

L

U2

147830 Honeywell #VR8205M1130 N

U3

147560 Honeywell #VR8205M1148

L

U6

150839 Honeywell #VR8305M4009 N

U7

150840 Honeywell #VR8305M4017 L

W6 172552 Honeywell #VR8105M2187 N

W7 172553 Honeywell #VR8105M2825 L

Advertising