6 installation – SeaLand DTD01 Discharge Pump Control User Manual

Page 7

Advertising
background image

7

6 Installation

1 . Select panel location away from direct contact with

water and oil .

2 . Confirm clearance for wire connections behind wall,

hull liner or bulkhead .

3. Using control panel template (fig. 8 , page 11), cut out

panel access hole (E, F) and drill fastener holes (G).

4 . With electrical power off, route 14-gauge stranded copper

wire from power source, through discharge pump circuit
breaker or fuse (not provided), to panel location. Route
additional wire according to diagram on page 3 or 4
(see wiring diagram keys below), depending on your
application, to panel location . Make sure wires extend
out through access hole .

5 . Make proper wiring connections to wires extending from

bottom of circuit assembly (fig. 2 4, page 2).

6. Remove panel cover (fig. 2 1, page 2) from mounting

frame (2) by carefully pulling them apart. Make sure wires
between key switch (3) and circuit assembly (4) remain
attached. (Key pin 1 – red; pin 2 – brown; pin 7 – blue.)

7. Install mounting frame to wall with four fasteners (5).

8 . Tuck key switch wires into circuit assembly housing,

and push panel cover onto mounting frame until it
locks into place .

9 . Turn on electrical power .

6.1

Tank Discharge Control Panel

(fig. 2 , page 2)

Control Panel Template
Dimensions

(fig. 8 , page 11)

2

Dometic Tank Discharge Control

Specifications

Caution!
Do not install DTD control panel in an atmosphere with potentially flammable or
explosive vapors.

Ref.

Dimension

A

83 mm (3.25 in.)

B

83 mm (3.25 in.)

C

67 mm (2.63 in.)

D

67 mm (2.63 in.)

E

55 mm (2.16 in.)

F

68 mm (2.69 in.)

G

2 mm (0.10 in.) dia.

H

Cut-out area .
Allow 51 mm (2 in.)
clearance behind wall .

8

8

2

2

ISO8846; EMC Directive 2004/108/EC

5.4 Approvals

5.3 Dimensions

(fig. 3 , page 2)

Ref.

Dimension

A

83 mm (3.25 in.)

B

83 mm (3.25 in.)

3

Ref.

Dimension

C

51 mm (2 in.) clearance behind wall

D

10 mm (0.38 in.)

Maximum relay rating for 12 or 24 V DC discharge pump: 20 amps.
Float Switch Rating: 20 watts with resistive load (when used with DTM04 system).