1 . Select panel location away from direct contact with water

and oil .

2 . Confirm clearance for wire connections behind wall, hull liner

or bulkhead .

3. Using control panel template (fig. 8 , page 5), cut out

panel access hole (E, F) and drill fastener holes (G).

4 . With electrical power off, route 18-gauge stranded copper

wire from power source, through circuit breaker or fuse (not
provided), to panel location. Route additional wire according
to diagram (fig. 4 , page 3 – see wiring diagram key
below), depending on your application, to panel location.
Make sure wires extend out through access hole .

5 . Make proper wiring connections to wires extending from

bottom of circuit panel (fig. 3 A 2, page 3).

6. Remove panel cover (fig. 3 A 1, page 3) from circuit panel/

mounting frame (A 2), if necessary, by carefully pulling them
apart .

7. Install mounting frame to wall with four fasteners (fig. 3 A 3).
8 . Push panel cover onto mounting frame until it locks into

place .

1. At step 4 (above), route and connect 14-gauge stranded copper wires according to wiring diagram

(fig. 4 , page 3) and wiring diagram key (see below).

2 . Insert “Full Tank” shut-down relay into receptacle on back of circuit panel .

6.1

Tank Monitor Panel

(fig. 3 A, page 2)

6.2

“Full Tank” Shut-down Relay (optional accessory)

(fig. 1 4, page 2)

DTM04 Panel Template
Dimensions

(fig. x , page 5)

3

1

Dometic Tank Monitor System

Specifications

Caution!
Do not install DTM04 panel in an atmosphere with potentially flammable or
explosive vapors.

Ref.

Dimension

A

83 mm / 3.25 in.

B

83 mm / 3.25 in.

C

67 mm / 2.63 in,

D

67 mm / 2.63 in.

E

55 mm / 2.16 in.

F

68 mm / 2.69 in.

G

2 mm / 0.10 in. dia.

H

Cut-out area .
Allow 51 mm / 2 in.
clearance behind wall .

6

6

4

4

43

3

3

5.3 Dimensions

(fig. 2 , page 2)

5.4 Approvals

ISO 8846; EMC Directive 2004/108/EC

Ref.

Dimension

A

83 mm / 3.25 in.

B

83 mm / 3.25 in.

C

51 mm / 2 in. clearance behind wall

D

10 mm / 0.38 in.

2

Ref.

Dimension

E

111 mm / 4.375 in.

F

25 mm / 1.0 in.

G

527 mm / 20.75 in.

H

69 mm / 2.75 in.