SeaLand TankMaster 6 User Manual

Page 2

Advertising
background image

TABLE OF CONTENTS

WARNING: When using this device, always exercise basic safety precautions, including the following:

Read all instructions before installation or use.

Never connect this device to any electrical circuit with other than 12 or 24 volt Direct Current or
exceed the amperage draw listed below.

Never install the control module in an atmosphere with potentially flammable or explosive vapors.

If installed within the hull, this product is not to be installed below the water line.

Control module provides an output signal for the analog Wema gauge using six level indica-
tions (two level indicator caps, three floats per cap) for all tanks up to 45 inches in depth.

Probe caps provide clean out for easy access to interior of tank.

Two different modes, automatic or manual, for holding tank discharge pump control.

The “manual” mode provides direct discharge pump control regardless of the level of the
holding tank.

The “automatic” mode will automatically maintain holding tank at empty level and eliminate
stagnating sewage trapped in interconnecting hoses by wye valve operation.

In the “automatic” mode, the 2

nd

, 3

rd

, 4

th

, or 5

th

float will turn on the discharge pump. This

provides many levels of backup in case of float switch failure.

Prevents accidental overboard discharge in restricted waters when control switch is turned to
“off” position.

Discharges sewage directly overboard in unrestricted waters while in the “automatic” mode.

Simplifies plumbing by eliminating wye valves, seacocks, and vented loops for multiple toilet
installations.

Outputs provided for, but does not include: analog Wema gauge, selector switch for automatic
or manual modes, full level alarm or light, ‘check seacock’ indicator light, seacock interlock
switch, and discharge pump.

12 and 24 VDC models available.

The TankMaster

6 Automatic Discharge Pump Controller is designed to provide several electrical

output signals in order to monitor and empty a holding tank system. An output for the analog
Wema gauge is obtained by making use of six level indication float switches. The TankMaster

6

also provides outputs for two different modes to empty a wastewater or greywater holding tank:
either automatic or manual. In the automatic mode, the 1/3 float switch (2

nd

float) will activate the

discharge pump. The pump will then run until the low-level switch (1

st

float) is de-activated. The

manual mode turns on the discharge pump regardless of the liquid level in the holding tank.

NOTE: Keep in mind that once you enter a no discharge zone, your TankMaster

must be

switched to the “off” position and the key removed to prevent illegally discharging your holding
tank. The United States Coast Guard will allow a key operated switch as a means to secure the
overboard discharge pump system instead of securing it with a padlock or wire tie.

SAFETY FEATURES

PRODUCT FEATURES

Safety Instructions

2

Product Features

2

System Operation Diagram

3

Models and Accessories

4

Specifications

4

Installation Instructions 5,
6

Wiring Diagrams

7

Dimensional Specifications

8

Parts List

9

Troubleshooting Guide

10, 11

Manufacturer’s One-Year Limited Warranty 12

2

Advertising