Installation instructions, Control panel – SeaLand TankMaster 6 User Manual

Page 5

Advertising
background image

5

INSTALLATION INSTRUCTIONS

CONTROL PANEL

1.

Select a mounting location away from direct contact with water and oil. Dry locations in the
bathroom, salon, or galley are most desirable.

2.

Confirm clearances for the panel behind walls, hull liner or bulkhead.

3.

Cut out mounting hole for control panel. (See template for cut-out and hole locations.)

4.

Do not mount the control panel until wiring is routed and secured to the terminal block or
rear of the control panel housing.

5.

Route wiring following the wiring diagram for blackwater or graywater applications.
PLEASE NOTE: remove jumper wire between pins 4 and 5 if the optional seacock interlock
switch is installed.

6.

Include wiring for any of the optional electrical accessories that may be part of the installation
and shown in separate wiring diagrams.

7.

Mount the control panel with the (4) #6 x 1-inch long black, oval-head screws provided.

8.

Insert the correct color lens in the appropriate hole from the front side of the faceplate,
snapping the matching light into the lens firmly. Color coding is as follows:

a) Green: Discharge Pump On
b) Yellow: Check Seacock (optional)

9.

Tuck the lead wires back into the housing so that the tension is taken off the switch in order
to allow the key to be turned freely. Insert the two (2) small tabs on the left side of the faceplate
into the housing, and snap the large center tab on the right of the faceplate into the housing to secure

it.

10.

NOTE: The TankMaster

®

4 comes with the lead wires (with female terminals from the

circuit board) attached to the keylock switch numbered tabs as follows:

a) Terminal 1: Red
b) Terminal 2: Brown
c) Terminal 7: Blue
d) Terminal 8: Red

Advertising