RESTORE FACTORY DEFAULT SETTINGS

To restore all features to the factory default settings (see following chart for default settings)

1. Turn the LO TEMP dial to access the Program Mode – indicated in the display as

Pro

2. Turn the HI TEMP dial to select feature

dEF

3. Push the Test/Settings Button to to reset all features to the default settings.
4. Reset LO TEMP and HI TEMP settings to desired temperatures (see page 11)

Dial

Setting

Feature

Options

Description

Default
Setting

Record

Your

Settings

1

Thermal Pre-Purge

OFF

On

Purge Inactive

Purge Active

OFF

2

Fahrenheit or Celsius

F

c

Degrees Fahrenheit

Degrees Celsius

F

3

LWCO Manual or

Automatic Reset

A

b

Automatic Reset

Manual Reset

A

4

Circulator Options

A

b

C

Circulator operation on T/TV call only
Circulator operation on I1/I2 call only
Circulator operation on call from either

A

Circulator Hold Off

Circulator Hold Off – Active

Circulator Hold Off – Inactive

Not available

on this control

Not available

on this control

Low Water Cut-Off

Function

Low Water Cut-Off ON

Low Water Cut-Off OFF

dEF

Restore Factory

Defaults

Y

n

Restore Defaults

Do Not Restore Defaults

n

*

SEE PAGE 18 FOR ADDITIONAL SETTINGS

*: “Circulator Hold Off” feature would be “Active” if defaults are restord. Turn it OFF (Inactive) if required.