Adjustment, Programming the radio receiver – Chamberlain LIFTMASTER PROFESSIONAL SW470 User Manual

Page 17

Advertising
background image

17

PROGRAMMING THE RADIO RECEIVER

SET SECURITY MODE

The Universal Receiver can be used with up to 15 315 MHz rolling
code remote controls or PINs in HIGH security mode. Alternately,
it can be used with up to 31 of any type 315 MHz remote control
in NORMAL security mode, including any combination of rolling
code, billion code, or dip switch remotes.

The jumper must be set at the HIGH position for the receiver to
operate in HIGH security mode. It must be set at NORMAL
position to operate at the NORMAL mode (Figure 1).

When changing from NORMAL to HIGH security mode, any
previous remote control codes must be erased. Repeat Steps 2
and 3 in the Programming Section below to reprogram the
receiver for each remote control in use.

The receiver is factory set at HIGH.

SET OUTPUT DURATION

For commercial applications, the receiver can be set for either
constant or momentary closure on the output contacts. Use of
constant closure is prohibited on residential garage door openers
because it overrides the safety reversal devices.

With the jumper in the “M” (Momentary) position, the contacts
will close for 1/4 second regardless of the length of radio
transmission. With the jumper in “C” (Constant) position, the
contacts will stay closed as long as the radio continues
transmitting (Figure 2).

The receiver is factory set at M.

PROGRAMMING THE REMOTE TO THE RECEIVER

1. Pry open the front panel of receiver case with a coin or a

screwdriver. Re-connect power to opener (Figure 3).

2. Press and release the “learn” button on the receiver. The learn

indicator light will glow steadily for 30 seconds.

3. Within 30 seconds, press and hold the button on the hand-held

remote that you wish to operate your garage door.

The opener will now operate when the push button on either the
receiver or the remote control is pressed.

Repeat Steps 2 and 3 for each remote control that will be used to
operate the garage door opener.

To erase all remote control codes:

Press and hold the “learn” button on the receiver panel until the
indicator light turns off (about 6 seconds). All remote control
codes are now erased. Then follow the steps above to reprogram
each remote control.

17

M

M

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of
this receiver and/or transmitter are prohibited, except for changing the code setting or replacing
the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.

24V

12V

HIGH

NORM

C

P2

M

Figure 1

Figure 2

Figure 3

A D J U S T M E N T

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing the

receiver.

To prevent possible SERIOUS INJURY or DEATH from a
moving gate or garage door:
• ALWAYS keep remote controls out of reach of children.

NEVER permit children to operate, or play with remote
control transmitters.

• Activate gate or door ONLY when it can be seen clearly, is

properly adjusted, and there are no obstructions to door
travel.

• ALWAYS keep gate or garage door in sight until completely

closed. NEVER permit anyone to cross path of moving gate
or door.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

WARNING

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

To prevent possible SERIOUS INJURY or DEATH, the use of
CONSTANT OPERATION on residential openers is

PROHIBITED.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

WARNING

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

Security Mode
Terminals

Jumper

HIGH

SECURITY MODE

Jumper

Security Mode
Terminals

Jumper

NORMAL

SECURITY MODE

Output
Duration
Terminals

Jumper

Output
Duration
Terminals

MOMENTARY
OPERATION

CONSTANT
OPERATION

Output Duration
Terminals

Power Supply Jumper

Security Mode

OPEN RECEIVER

OPENING RECEIVER

Indicator Light

Learn Button

Connect
Antenna

Advertising
This manual is related to the following products: