T H R E E P H A S E W I R I N G D I A G R A M ( S W 4 9 0 )

DRAWING NUMBER:

01-G1979-3

DATE:

7/29/03

REVISION:

E

ECN:

03-0401

NOTES:

1) TRANSFORMER PRIMARY VOLTAGE SAME AS OPERATOR LINE VOLTAGE

24V SECONDARY 60VA.

2) WIRE COLOR: 208V RED, 230V ORANGE, 460V VIOLET, 575V GRAY

3) OPTIONAL WIRE HARNESS (SEE DRAWING 90-G0532).

4) OVERLOAD PROTECTION EITHER IN MOTOR OR FROM AN EXTERNAL

OVERLOAD.

5) (B+) AND (B-) ARE 100dB SAFETY ALARMS.

APPLICATIONS:

CONTROL WIRING TYPE - GL

FIELD WIRING & ADJUSTMENTS

MODEL TYPES:

SW490 (HSW)

HORSEPOWER:

1/2, 3/4 & 1

VOLTAGE/PHASE:

208,230,460 & 575V - 3 PHASE ONLY

845 Larch Avenue, Elmhurst, IL 60125

'

'

'

'

Note 1

24V
Sec.

R

R 2

2

R

R 4

4

R

R 3

3

R

R 1

1

R

R 2

2

R

R 3

3

R

R 4

4

J4

1

2

24 Vac - IN

24 Vac -COMMON

+24 Vdc

SOFT OPEN

“B” LIMIT

“A” LIMIT

CONTACTOR B

CONTACTOR A

RPM - IN

RPM GND

RPM - SUPPLY

RADIO COMMAND

SHADOW

CLOSE

STOP

SOFT OPEN

HARD OPEN

INT. LOOP

OBS. OPEN

NC

OBS. CLOSE

DC - GND

LOCK 1

LOCK 2

ALARM 1

ALARM 1

24 Vac - COMMON

GL CONTROL BOARD

ALARM ASSY

76-G0564

ALARM ASSY
76-G0564

208/230V MOTOR

O/L
NOTE 4

ON/OFF
SWITCH

460V MOTOR

575V MOTOR

J2 PLUG

J2 PLUG

LEGEND

(OPTIONAL)

TERMINAL BLOCK

J1 TERMINAL BLOCK

PERMANENT TERMINAL

RPM SENSOR

SEE NOTE 5

SEE NOTE 4

SEE NOTE 2

3 PHASE

POWER IN

DUAL GATE

24 Vac

RADIO
SIGNAL

B+

B-