O P E R A T O R M A I N T E N A N C E

NOTES

1. Severe or high cycle usage will require more frequent

maintenance checks.

2. Inspection and service should always be performed anytime a

malfunction is observed or suspected.

3. Limit switches may have to be reset after any major drive chain

adjustments.

4 If lubricating chain, use only a proper chain lube spray or a

lightweight motor oil. Never use grease or silicone spray.

RPM Sensor (Hall Effect)

Check for proper adjustment

X X

External Entrapment

Check for proper operation

X X

Protection Systems

Gate Caution Signs

Make sure they are present

X X

Manual Disconnect

Check and operate

X X

Drive Chain

Check for excessive slack and lubricate

X X

Sprockets and Pulleys

Check for excessive slack and lubricate

X X

Gate

Inspect for wear or damage

X X

Accessories

Check all for proper operation

X X

Electrical

Inspect all wire connections

X X

Frame Bolts

Check for tightness

X X

Total Unit

Inspect for wear or damage

X X

DESCRIPTION

TASK

3 MONTHS

6 MONTHS

12 MONTHS

CHECK AT LEAST ONCE EVERY

5. When servicing, please do some “house cleaning” of the

operator and the area around the operator. Pick up any debris
in the area. Clean the operator as needed.

6. It is suggested that while at the site voltage readings be taken

at the operator. Using a Digital Voltmeter, verify that the
incoming voltage to the operator it is within ten percent of the
operators rating.

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of SEVERE INJURY or DEATH:

1. READ AND FOLLOW ALL INSTRUCTIONS.
2. NEVER let children operate or play with gate controls. Keep

the remote control away from children.

3. ALWAYS keep people and objects away from the gate. NO

ONE SHOULD CROSS THE PATH OF THE MOVING GATE.

4. Test the gate operator monthly. The gate MUST reverse on

contact with a rigid object or stop when an object activates
the non-contact sensors. After adjusting the force or the
limit of travel, retest the gate operator. Failure to adjust and
retest the gate operator properly can increase the risk of
INJURY or DEATH.

5. Use the emergency release only when the gate is

not moving.

6. Keep gates properly maintained. Read the owner’s

manual. Have a qualified service person make repairs to

gate

hardware.

7. The entrance is for vehicles ONLY. Pedestrians MUST use

separate entrance.

8. Disconnect ALL power BEFORE performing ANY

maintenance.

9. ALL maintenance MUST be performed by a LiftMaster

professional.

10.

SAVE THESE INSTRUCTIONS.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

WARNING

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

Advertising
This manual is related to the following products: