SOFT OPEN

1 2 3 4 5 6 7 8 9 10

INTERRUPT (SAFETY) LOOP INPUT

5 8 9 10 11 12

21

ACCESSORY WIRING

All inputs are normally open and momentary, except the stop
(N.C.). The following instructions are based upon UL325, and
include recommendations for significant increase in safety.

We strongly recommend that you follow the UL guidelines
presented throughout the manual. Refer to instructions shipped
with optional control devices for mounting, wiring, programming
and adjustment.

24 Vac Accessory Power

Can be found at terminals R1 and R2 located on radio terminal
block.

J1 Terminals 1 & 5 - Residential Radio (single button) Input

These terminals are intended for use with a radio receiver in a
residential application or as a single button control. This allows
the user to open the gate by activating the remote control when
the gate is closed or between limits. This input also gives the user
the ability to close the gate by activating the remote control when
the gate is on the open limit.

J1 Terminals 2 & 5 - Shadow Loop Input

These terminals are intended for use with a loop detector and is
primarily used on swing gate operators. This input protects cars
by preventing the gate from moving off of the open or close limit
when the shadow loop input is active.

J1 Terminals 6 & 5 - Soft Open

These terminals are intended for use as a general open control.
Accessories that may be wired to this input include: Telephone
Entry Systems, Radio Receiver (Commercial Applications), Exit
Loop Detector, Keypads, 7-Day Timer.

NOTE: Will not override a double entrapment (signalled by the
gate stopped and entrapment alarm on).

Field Wiring Terminals 8 & 5 - Interrupt (Safety) Loop Input

These terminals are intended for use with a loop detector. This
input functions to reverse a closing gate to the open limit.
Latching this input will reset the timer to close.

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

R2

R1

R4

R3

24 Vac

FR

EQ

FRE

Q

FRE

Q

3

6

9

#

2

5

8

0

1

7

A D J U S T M E N T

J1 Terminal Block

Control Board

ONE BUTTON WIRING

1 2 3 4 5 6 7 8 9 10

SHADOW LOOP INPUT

1 2 3 4 5 6 7 8 9 10