Chamberlain SL 1000-XI User Manual

Page 14

Advertising
background image

Rev C

Doc

6001194

(01-20259)

11 of 36

NOTES:

1.

Overload setting (R72) is factory set. Do not adjust.

2.

Current flow varies with temperature. Do not tune the sensitivity measurements too

finely, or they may change with the time of day or seasons.

♦ If your installation requires setting switch S1 the “Open to Right” position, use the “Open to

Right" adjustment procedures below. If your installation requires setting S1 to the “Open to
Left” position, use the “Open to Left" adjustments following the "Open to Right" procedures.

♦ The minimum sensitivity is full clockwise and maximum sensitivity is full counter clockwise.

These adjustments must be made while the gate is in motion.

♦ Before starting the adjustments, verify that the overload pot is set to 3:00 o'clock, the Left and

Right reverse pots are set fully clockwise, and the Inrush pot is set to the 11 o’clock position.

♦ Make all adjustments in the order listed.

Figure 15. Gate Sensitivity Adjustments Location.

"OPEN TO RIGHT" ADJUSTMENT PROCEDURES

Right Gate Motion Adjustment (R69)
1. Initiate opening the gate.
2. Wait 4 to 5 seconds, then lightly "tug"against the edge of the gate to simulate an obstacle.
3. If the gate does not stop, reclose the gate and adjust the pot slightly counterclockwise.
4. Repeat steps 1-3 until the gate stops when tugged and has the desired sensitivity.
Left Gate Motion Adjustment (R160)
1. Open the gate fully, then initiate closing the gate.
2. Wait 4 to 5 seconds, then lightly "bump" the leading edge of the gate to simulate an obstacle.
3. If the gate does not stop or back up, reopen the gate and adjust the pot slightly

counterclockwise.

4.

Repeat steps 1-3 until the gate stops or backs up when bumped and has the desired
sensitivity.

Advertising