13. GATE DOES NOT CLOSE AUTOMATICALLY

1. Reclose timer setting is disabled.
2. The entry system is connected to Manual open by mistake.
3. An input is continuously activated (stuck ).

14. OPERATOR DOESN'T RESPOND TO COMMANDS FOR A MINUTE

A fault has occurred and Max Retry count (programming step 9) is set to 0.

15. ALTERNATE ACTION DOES NOT WORK

1. ATG and Reclose Timer are enabled.
2. Entry system is connected to the Manual Input by mistake.

16. GATE DOES NOT OPEN TO THE CORRECT DIRECTION

1. The power was not cycled after changing the setting of switch S1.

17. AN OPEN GATE DOES NOT CLOSE AT POWER UP

1. An input is continuously activated (Stuck).
2. The gate was not on the open limit switch when the power went out.
3. Reclose Timer is disabled.

18. GATE DOES NOT MOVE AFTER POWER OUTAGE

1. Bad Power Fail Option battery.
2. Miswired DC motor inputs.
3. Bad connection between the Power Fail Option harness connector and the Control Board.
4. Power Fail Option Open direction (switch S2) is not set to the correct position.
5. Battery is connected backwards, causing resettable fuse on the control board to open.

19. POWER FAIL OPTION WORKS, BUT GATE DOESN'T STOP AT LIMIT

1. Miswired DC motor inputs.
2. Bad Power Fail Option harness.

20. BATTERY DOESN'T RECHARGE WITHIN 4 TO 5 HOURS AFTER USE

1. Old or bad battery.
2. Bad harness.
3. Bad Control board.

21. POWER FAIL OPTION MOVES THE GATE TOO SLOWLY

1. Old or not fully charged battery.
2. Hardened or frozen gate wheels.
3. Slipping belt.

4.

Belt is too tight.