L. POST INSTALLATION PROCEDURES

1. Setup

1. Turn on the main power at the gate operator's circuit breaker.
2. Verify that switch S1 (the Gate Open Direction switch) is set to the correct position.
3. Turn on the unit power switch (on master/slave systems, turn on slave and then master).

2. Manual inputs

1. Verify that Manual Open fully opens the gate and that the open limit switch stops the gate.
2. Verify that Manual Close fully closes the gate and that the close limit switch stops the gate.
3. Verify that Manual Stop stops the gate.
Note: If the gate stops due to a Reverse Fault, readjust the gate sensitivity pot.

3. Mechanical

Use the Manual Input commands to verify that:
1. The gate rolls open and closed smoothly.
2. There is no squeak or vibration in the gate when it is moving .
3. There is no belt slippage when the gate moves or stops.
4. There is no slack in the closed gate due to loose chain or parts.
5. Both gates open and close at the same time (Bi-Parting gates only).

4. Gate sensitivity

1. Left/Right Reverse sensitivity:

Apply a bump to the opening and closing gate and verify that the gate stops or reverses.

2. Inrush (Gate response time) :

Apply a bump to the gate as it initiates opening and closing and verify that the gate
responds to the bump within a second.

5. Maximum Retry Count

1. If you want the gate to resume operation automatically once or twice after a Fault, enter 1 or

2 in programming step 9.

2. If you do not want the gate to resume automatically after a Fault, enter 0.
3. Give the opening gate a quick bump to generate a fault and verify retry operation.
NOTE: Programming steps 10 through 14 allow further gate control after a fault.

6. Entry inputs

1. Activate the OPEN input (entry system), RADIO input (radio transmitter), and EXIT Loop

input (driving over the exit loop) and verify that they fully open the gate. If Reclose Timer is
enabled, it will close the gate.

2. Activate the FIRE input (fire department switch) and verify that the gate fully opens and then

closes immediately. If Reclose Timer is enabled, it will close the gate.