39

• The floor is the deepest depth at which the decompression stop time will not

increase. Decompression will start when you pass this depth during your ascent.

• The decompression range is the depth range between the ceiling and floor.

Within this range, decompression takes place. However, it is important to remem-

ber that the decompression will be very slow at, or close to, the floor.

The depth of the ceiling and floor will depend on your dive profile. The ceiling depth

will be fairly shallow when you enter the decompression mode, but if you remain at

depth, it will move downward and the ascent time will increase. Likewise, the floor and

ceiling may change upwards while you are decompressing.

When conditions are rough, it may be difficult to maintain a constant depth near the

surface. In this case it will be more manageable to maintain an additional distance

below the ceiling, to make sure that the waves do not lift you above the ceiling. Suunto

recommends that decompression takes place deeper than 4 m [13 ft], even if the

indicated ceiling is shallower.

NOTE

It will take more time and more air to decompress below the ceiling

than at the ceiling.

WARNING NEVER ASCEND ABOVE THE CEILING! You must not ascend above

the ceiling during your decompression. In order to avoid doing so by

accident, you should stay somewhat below the ceiling.