3.4.3. Oxygen Limit Fraction (OLF)

In addition to tracking the diver’s exposure to nitrogen, the instrument tracks the

exposure to oxygen, if set to Nitrox mode. These calculations are treated as entirely

separate functions.

The dive computer calculates separately for Central Nervous System oxygen toxicity

(CNS) and Pulmonary Oxygen toxicity, the latter measured by the addition of Oxygen

Toxicity Units (OTU). Both fractions are scaled so that the maximum tolerated exposure

for each is expressed as 100%.