CAUTION When the battery is changed all nitrogen and oxygen uptake data

is lost. Therefore, the no-flying time shown by the computer should

have reached zero or you must wait for 48 hours or preferably even

100 hours between dives before you may dive again.

All history and profile data, as well as the altitude, personal and alarm settings, will

remain in the dive computer memory after the battery change. However, the clock

time and time alarm setting is lost. In the NITROX Mode the Nitrox settings are also

reverted back to default settings (21 % O

2

, 1.4 bar PO

2

).

When working with the battery compartment, cleanliness is extremely important. Even

the smallest dirt particles may cause a leakage when you dive.

BATTERY KIT

The battery kit includes a 3.0 V coin type lithium cell battery and a lubricated O-ring.

When handling the battery do not make contact with both of the poles at the same

time. Do not touch the surfaces of the battery with your bare fingers.

TOOLS REQUIRED

• A flat 1.5 mm screwdriver or a special tool for spring bars (K5857).

• Soft cloth for cleaning.

• Needlenose pliers or large screwdriver for turning securing ring.