TABLE 3.3. WARNING SYMBOLS

Symbol on display

Indication
Diver Attention Symbol - Extend Surface Interval

Violated Decompression Ceiling

Do Not Fly Symbol

If you start a new dive with less than 5 minutes of surface interval time, the dive computer

interprets this as a continuation of the previous dive and the dives are considered to

be the same. The diving display will return, the dive number will remain unchanged,

and the dive time will begin where it left off. After 5 minutes on the surface, subsequent

dives are, by definition, repetitive. The dive counter displayed in the Planning Mode

will increment to the next higher number if another dive is made.

3.5.3. Flying After Diving

The no-flying time is shown in the center window next to the airplane image. Flying

or travelling to a higher altitude should be avoided at any time the computer counts

down the no-flying time.

NOTE

The airplane symbol is not shown on the stand-by display. You should

always activate the dive computer and check that the airplane symbol

is not displayed prior to flying.