Tm-u295, Tm-u295 -16, 16 installation – Triner Scale TMU-295 User Manual
Page 27
Advertising

1-16
Installation
TM-U295
Switch
Function
ON
OFF
1
Data reception error
Ignored
Prints”?”
2
Receive buffer capacity
35 bytes
512 bytes
3
Handshaking
XON/XOFF
DTR/DSR
4
Word length
7 bits
8 bits
5
Parity check
Yes
No
6
Parity selection
Even
Odd
7
See Transmission Speeds table below.
8
9
Pin 6 reset signal
Used
Not used
10
Pin 25 reset signal
Used
Not used
Transmission Speeds
Speed in Bits per Second
SW 7
SW 8
1200
ON
ON
2400
OFF
ON
4800
ON
OFF
9600
OFF
OFF