* If remote operation is selected or deselected, the user has to ensure

that no dangerous status of the system can occur due to the change of

the mode of operation, and must also take appropriate safety precau-

tions, especially if selecting remote operation interferes with a locally

operated active process.

** With command ”ECHO 1” a return value can be activated at write com-

mands. A return value is only given if the command is performed cor-

rectly.

*** After being switched on, the controller is in ”CVC 2” mode by default.

Send ”CVC 3” and ”STORE” to permanently set the controller RS 232C

commands to the extended set ”CVC 3000”.

Accessories

External pressure transducer VSK 3000, ..................................................636657

capacitive, ceramic diaphragm sensor 810 - 0.1 Torr (1080 - 0.1 mbar)

Coolant valve VKW-B, VACUU•BUS ...........................................................674220

Venting valve VBM-B / KF 16, VACUU•BUS .............................................. 674217

VACUU•BUS Y-type adapter ......................................................................636656

VACUU•BUS extension cable, 6.6ft (2m) ....................................................612552

VACUU•BUS wall jack .................................................................................636153

Serial cable RS 232C, 9-pin, Sub-D .............................................................637837

Installation set CVC 3000 (clips and screws) ..............................................636593

Level sensor.................................................................................................699908

(control of liquid level in catchpots)

VACUU•BUS Digital-I/O-Module .................................................................636228

(e.g., fault indicator / remote module)

VACUU•BUS Analog-I/O-Module ................................................................636229

(for analog input and output of vacuum and motor speed)

VMS-B module 100-230V 50/60Hz (with connection cable) ........................676030

PC-Software VACUU•CONTROL .................................................................692920

Use VACUU•BUS Y-adapters and extension cables to connect further

components. When connecting an external pressure transducer, it is

used automatically. Further information on how to use several sensors

simultaneously is available on request.