2 notes on developing application 142 – Casio IT-2000W User Manual

Page 142

Advertising
background image

142

8.2 Notes on Developing Application

 The use of double clicks on this terminal extremely difficult. Develop your application program

so that only single click is enabled

 Any program that uses the COM port must turn on the power to it in advance using the system

library. The power to the COM port remains on once it has been turned on, or until it is turned

off by the system library or until the RESET button is pressed. Therefore, do not forget to turn

off the power to the COM port when it is no longer required. This power is automatically

turned off during the suspend state, but power is restored to it if system operation is resumed.

Accordingly, the application program side does not have to be aware of the power condition.

 If a program is running on MS-DOS/MS-Windows, data may not always be written in the

physical disk each time the file write function is called. MS-DOS/MS-Windows will hold the

write data in memory until a given amount of data is accumulated. Do not turn the power off

and on or remove and insert the card if this occurs. If this event occurs, the programmer should

create an application which calls the COMMIT command form MS-DOS after attempting a

write to the disk. This COMMIT function can also be called using the _dos_commit () function

of Microsoft-C.

 While a file in SRAM card is being opened under Windows, the operation of the access to the

card is aborted if suspend is executed. This will cause INT24 error when the access to the

SRAM card for writing or closing is continued after the resume. When you use an SRAM card

under Windows, please be sure to perform the operation steps in sequence of “open

 write 

close”.