Transmission of Command

Transmits a command represented by a single ASCII code to the OBR. Various options including

"Readout mode", "Data transfer format", etc., can be set for this transmission. This setup does not

have to be made each time the power is turned on if it is written in the EEPROM.

For information about the setup procedure refer to "Setting Operation Mode/DT-9650BCR"

on page 223.

SYNTAX

#include "obrlib.h"

int FAR PASCAL _export OBR_Send(char far *pszcmd);

INPUT

pszcmd = pointer to command buffer (refer to the Command List.)

OUTPUT

= 0 : Normal termination

= 1 : Transmission error

Note :

This is to transfer command to OBR. For detail of each OBR command, refer to operation mode

setting of each OBR command.