8.6.6 FLINK Library

Overview

The FLINK library (FLINK.DLL) is a utility used to perform communication between two IT-2000

terminals or between the terminal and a personal computer via the infrared communication interface

(IrDA). It is a 16-bit dynamic link library (DLL). The FLINK function is called from its external

function.

WIN.INI setups

Various setups of the FLINK.DLL are defined in the WIN.INI file. The setup procedure with the

WIN.INI is explained below.

 Setup of the IrDA communication speed (MaxBaudRate)

The maximum possible baud rate of the IrDA is specified by "MaxBaudRate" in the WIN.INI

file.

Example

Setting the maximum possible baud rate to 4 Mbps

MaxBaudRate = 4000000

 Setup required for IrDA communication between two HTs (DiscoverCount)

For two HTs to communicate with each other, "DiscoverCount" in WIN.INI must have a

different setting on the primary side and secondary side. For communication via the I/O Box, set

up the WIN.INI file of the HT on the secondary side.

 Set DiscoverCount = 4 on the primary side.
 Set DiscoverCount = 0 on the secondary side.