Carrier 38QF User Manual

Page 12

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Compressor Removal

— See Table? for com­

pressor information and Fig. 21 for component
location. Shut off power to unit. Remove refrigerant

from unit using refrigerant removal methods de­

scribed in Carrier Standard Service Techniques
Manual, Chapter 1, Refrigerants.

Be sure system pressure is 0 psig before

proceeding.

Table 7 — Compressor Data (60 Hz)

UNIT
38QF

PRODUCTION COMPRESSOR

V/PH

Model*

Oil Recharge

Ounces

018

230/1

H22B173ABCA

37

024

208-230/1

CRC2-0175-PFV

51

030

208-230/1

CRF1-0250-PFV

51

036

208-230/1

CRG1-0251-PFV

51

042

208-230/1

CRJ1-0301-PFV

51

048

230/1

PC4616CD

66

060

230/1

PC6016BD

66

*Refer to Carrier Service Parts Catalog for replacement com­

pressor model numbers.

STRAINER VAPOR REVERSING

\ LINE VALVE

\

OUTDOOR COIL

ACCUMULATOR

MUFFLER SOLENOID

COIL

HOT GAS
DISCHARGE LINE

COMPRESSOR

Fig. 21 — Component Location

Follow safety codes. Wear safety glasses and

work gloves. Have quenching cloth available.

CATTIO.N; .'Mumimim tubing is used in unit
coils. Do not o\erlieat or place c.xcessi\c .strain
on lubinii or damce inav result.

1

.

2

.

3

.

Remove top cover as described in Installation,
Step I.

Disconnect high- and low-voltage field wiring

and fan motor leads from capacitor and
contactor.

Remove screws holding discharge grille in place.
Lift grille from unit.

Disconnect compressor leads (crankcase heater,
low-pressure switch, defrost thermostat and

solenoid coil) from electrical components and

pull them thru the wire access opening into the
coil section. Lift fan orifice/control ring after
pinching and pressing down on 3 plastic pins of
tube supports.

5.

Remove louvered casing by taking out screws

securing it to the cabinet and sliding it away
from the coil.

Using a midget tubing cutter, cut liquid and
discharge lines on the coil and suction and dis­

charge lines at a convenient place near the com­
pressor for easy reassembly with copper slip

couplings.

C.\LTJO\: F.xcvssivc movement of copper
lines at compressor may cause a break where
lines connect to condenser coil.

6

.

7. After plugging connections, remove condenser

coil by pinching plastic pins of tube supports
that extend into basepan and lift vertically. Set
coil on a clean, flat surface.

8. Remove compressor holddown bolts and slide

out compressor. Remove crankcase heater.

W A R N I N G : For bra/ing and unbrazing

have lire extinguisher and or quenching
cloth available in case oil vapor ignites.

9. Carefully unbraze suction and discharge line

piping stubs from compressor after noting posi­
tion of stubs to assist when reinstalling.

10.

Install new compressor, placing crankcase

heater around compressor. Be sure compressor
holddown bolts are in place.

11. Replace coil; braze suction and discharge lines

to compressor piping stubs (at points where cut.
Step 6); rewire compressor and leak test.

12. Replace fan orifice/control ring; connect com­

pressor wires after feeding them thru control
ring; replace fan/grille assembly and rewire;
connect high- and low-voltage power wiring;
and replace louvered casing.

13. Replace top cover by running 4 screws into

orifice loosely (2 on each side of unit) and

tighten when cover is in place. Replace remain­
ing screws.

14. Evacuate and recharge system.

Filter Drier

— Install field-supplied filter drier

(Table 3) in system liquid line when refrigerant
system is opened for service as described under

Compressor Removal. Position drier in liquid line

at convenient location.

Pumpdown Procedure

— The system may be

pumped down in order to make repairs on low side
without losing complete refrigerant charge.

1. Attach pressure gage to suction service valve

gage port.

2. Frontseat the liquid line valve.

12

Advertising