Fig. 5 — control circuit connections – Carrier 38QF User Manual

Page 6

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

THERMOSTAT

SUBBASE

HH93AZI73

OR HH93AZI75

40AQ.40FQ OR 40QB FAN COIL

38QF

COOLING CONTROL KIT

TERM INAL

TERMINAL BOARD

BOARD

COOLING AND ONE-STAGE HEATING

(38QF/40AQ 0R40QB/QB WITHOUT ELECTRIC HEATER)

A

THERMOSTAT

SUBBASE

HH93AZI73

OR HH93AZI75

40AQ,40FQ OR 40QB

ELECTRIC HEATER
TERMINAL BOARD

38QF

TERMINAL

BOARD

EQUIPPED WITH ELECTRIC HEATER;

SUPPLEMENTAL HEAT, ONE OUTDOOR THERMOSTAT)

THERMOSTAT

SUBBASE

HH93AZ173

40AQ,40FQ OR 40QB

ELECTRIC HEATER

TERMINAL BOARD

38QF

TERMINAL

BOARD

THERMOSTAT

SUBBASE

40AQ,40FQ OR 40QB

ELECTRIC HEATER

38QF

TERMINAL

COOLING AND TWO-STAGE HEATING

(38QF WITH 40AQ, 40QB/QH OR 40FS/28VQ

EQUIPPED WITH ELECTRIC HEATER;

SUPPLEMENTAL HEAT, NO OUTDOOR THERMOSTATS)

B

COOLING AND TWO-STAGE HEATING

(38QF WITH 40FS/28VQ

EQUIPPED WITH ELECTRIC HEATER;

SUPPLEMENTAL HEAT, TWO OUTDOOR THERMOSTATS)

SHR — Supplemental Heat Relay
ODT — Outdoor Thermostat
_______ Factory Wiring
_______ Field Wiring

*Transformer (60 va) located in cooling control kit or electric heater.
fRemove factory-installed jumper (Connection B) when installing outdoor thermostats (ODT).

Fig. 5 — Control Circuit Connections

Accessory Outdoor Thermostat

provides adjust­

able outdoor control of accessory electric heater.
This thermostat makes contact when a drop in out­
door temperature occurs. It energizes a stage of elec­
tric heat when the outdoor temperature setting is

reached, provided the room thermostat is on the
second stage of heating. One outdoor thermostat is

recommended for each stage of electric heat after the
first stage. Set the outdoor thermostat(s) progres­
sively lower for each stage. Refer to heat load of

building and unit capacity to determine the correct

outdoor thermostat settings.

The accessory supplemental heat relay is required

when 2 outdoor thermostats are used. It is auto­
matically energized by the manually operated sup­
plemental heat switch in the indoor thermostat

subbase. The thermostat locks out compressor and
the relay bypasses the outdoor thermostats for

electric heater operation during heat pump shut­
down. When one outdoor thermostat is used a

supplemental heat relay is not required. The sup­
plemental heat switch in the indoor thermostat

subbase bypasses outdoor thermostat, locks out
compressor and activates electric heater.