Fig. 3 — floor opening, 58drc counterflow gas-fired furnaces, Table 2 — dimensions (in.) – Carrier 58DRC User Manual

Page 2

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

HEATING & COOLING

58DRC

Counterflow Gas-Fired Furnaces

Table 2 — Dimensions (in.)

SIZE

58DRC

A

B

C

VENT

045

17

'/2

15%

16

4

065

17

'/2

15%

16

5

080

21

19%

19'/2

5

095

24'/2

22’%e

23

6

2. Construct hole in floor per dimensions in Fig. 3 and

Table 4.

3. Place plenum and furnace as shown in Fig. 4.

HOLE IN FLOOR

FURNACE

-fc-SHEET METAL

PLENUM

Fig. 4 — Furnace on a Concrete Slab

Table 4 — Floor Opening Dimensions (in.)

SIZE 58DRC

A

045, 065

16%6

080

19%

095

23'/i6

INSTALLATION ON A COMBUSTIBLE FLOOR

I. Read Installation Instructions packaged with com­

bustible floor base. See Fig. 5.

Cut and frame hole in floor per dimensions in Fig. 3

and Table 4. If this requires cutting a floor joist, tie

ends of cut joist into adjacent joists so that proper floor
support is maintained.

Assemble and install combustible floor base per in­

structions packaged with base.

When completed, combustible floor base, plenum,

and furnace (or coil casing when used) should be

installed as shown in Fig. 6.

2

.

3.

Fig. 3 — Floor Opening

Table 3 — Ratings and Performance*

SIZE

58DRC

INPUT

BTUH

HEATING

CAPACITY

(BTUH)**

TEMP

RISE

RANGE (F)

HEATING!

COOLING!

MOTOR HP

(PSC)

APPROX

SHIP. WT

(lb)

Ext Static

Pressure

(in. wg)

CFM

Ext Static

Pressure

(in. wg)

CFM

045CB

60,000

45,000

30-60

12

1080

0 5

1206

'h

157

065CB

80,000

65,000

30-60

12

1240

0.5

1630

'/2

170

080CB

100,000

80,000

40-70

15

1165

0 5

1620

'/2

187

095DB

120,000

95,000

40-70

20

1830

0.5

2075

'/2

227

PSC

— Permanent Split Capacitor

‘Ratings are certified for altitudes to 2000 feet For elevation above 2000 ft, reduce ratings 4% for

each 1000 ft above sea level

tCFM at #3 speed tap
|CFM at #1 speed tap

“Preliminary data.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Bookll 14

PC 101

Catalog No 535-843

PrintedinUSA

Form58DRC-1SI

Pg2

7-85

Replaces: New

For replacement items use Carrier Specified Parts