HEATING A COOLING

58DRC

Counterflow Gas-Fired Furnaces

START-UP AND ADJUSTMENT

In addition to the following information, refer to

Procedures for Gas-Fired Furnaces packaged with the

unit.

NOTE: There is a switch located in the blower compart­
ment that breaks the electrical power supply when the

blower access door is removed. Be sure blower access

door is properly installed.

A CAUTION

This furnace is equipped with a fusible link in the

vestibule area that will melt if an overheating condi­
tion caused by an inadequate combustion air supply
or improper venting practices develops. Do not

jumper this fuse. Correct the condition and replace

the fuse with an identical part.

The gas service pressure must not exceed 14 in. wg

(8.1 oz) for natural gas, or 11 in. wg (6.3 oz) for LP
(propane) gas.

NOTE; The gas valve regulator has been factory-set at

3 5 in. wg for natural gas and 10.5 in. wgfor LP (propane)

gas. Refer to Procedures for Gas-Fired Furnaces when

checking input.

Adjustment of Blower Speed

A WARNING

Disconnect the electrical power before changing the

speed tap.

To change motor speed taps, remove the motor tap

lead (see Table 5) and relocate it on the desired terminal
on the plug-in terminal block/speed selector located on

the blower.

A

CAUTION

When adjusting the blower speed, make certain that

the temperature rise across the heat exchanger does
not exceed that specified on the rating plate.

Table 5 — Speed Selector

SPEED

COLOR

TAP NO.

Common

White

C

Hi

Black

1

Med-Hi

Yellow

2

Med-Low

Blue

3

Low

Red

4

Automatic Gas Control Valve — These units are

equipped with an automatic gas control valve. See

Fig. 13. If not already checked when lighting the main

burner, check the proper operation of this valve by
moving the room thermostat pointer above and below
room temperature and observing that the main burners

light on call for heat and go off when the pointer is moved

below room temperature setting.

REGULATOR
ADJUSTMENT

MANUAL

ON-OFF

DIAL

, ~ .

^ PILOT

ADJUSTMENT

PILOT
TUBE
CONNECTION

Fig. 13 — Redundant Automatic Gas Control

Valve — BDP Model 646

NOTE: For ease of adjusting the pilot flame, disconnect
one power lead at main gas valve. For Model 646 gas

valve, disconnect terminal no. 1. This will prevent main

burner ignition and allow time to adjust the pilot. Re­

connect the power lead after adjustment.

CARE AND MAINTENANCE

A

CAUTION

Because of possible damage to the equipment or per­

sonal injury, maintenance should be performed by
qualified service agency.

A

WARNING

Never store anything on, or in contact with, the
furnace, such as

1 Spray or aerosol cans, rags, brooms, dust mops,

vacuum cleaners, or other cleaning tools.

2. Soap powders, bleaches, waxes or other cleaning

compounds, plastic or plastic containers, gas­
oline, kerosene, cigarette lighter fluid, dry clean­
ing fluids, or other volatile fluids.

3, Paint thinners and other painting compounds,

paper bags or other paper products

For continuing high performance, and to minimize

possible equipment failure, it is essential that periodic

maintenance be performed on this equipment. Consult
your local dealer as to the proper frequency of mainte­

nance and the availability of a maintenance contract

The ability to properly perform maintenance on this

equipment requires certain mechanical skills and tools.

If you do not possess these, contact your dealer for
maintenance.

A

WARNING

Turn off gas and electrical supplies to unit before

performing any maintenance or service on unit.

Follow relighting instructions on plate attached to

furnace

/ ■