Step 9 — reverse components (if required), A warning, A caution – Carrier 580PB User Manual

Page 11: Fig. 8 — accessory filter rack assembly, Step 9 — reverse components, If required) -13, 58ed,pb horizontal gas-fired furnaces, Warning, Caution

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

HEATING & COOLING

58ED,PB

Horizontal Gas-Fired Furnaces

Use only copper wire for 115v supply service to

furnace. When replacing any original wiring, use only

105 C, 16 gage AWG copper wire.

Instructions for wiring the thermostat are packaged

with the thermostat (field supplied). Make connections
as shown in wiring labels at the 24 v terminal board
located on the electrical junction box. When installing
accessories

to

this

furnace,

follow

manufacturer’s

instructions included with the accessory Except for
thermostat wiring, a minimum of typeT (63 F rise) must
be used.

Step 8 — Install Filters

— Filters and racks are

available as accessories. See Fig. 8 for recommended
filter size rating and type.

IMPORTANT: All furnaces must be equipped with
a filter.

Step 9 — Reverse Components

(if required).

A

WARNING

Before proceeding with component reversal, make
sure that all power is turned off upstream of furnace

and all gas piping is shut off and disconnected from
furnace.

A

CAUTION

Before proceeding with field reversing, ensure a

correct wiring diagram is available and/or be
prepared to mark all wiring as it is disconnected.

INPUT

A

(iOOO BTUH)

(IN)

50

I4i

75

100

I6|

125

20i

140

I5Î

note

;

FILTER RACK TO INLET
END OF FURNACE INSTALLED
INTO RETURN DUCTWORK.

Fig. 8 — Accessory Filter Rack Assembly

All references to left or right side of furnace refer to

the furnace looking at the heat exchanger (supply
air side).

The gas valve, pilot burner components and controls

may be reversed as follows:

1

Loosen burner removal cover screws and remove

both covers

2

Disconnect all wires to gas valve and unplug the

igniter cable from the ignition control (if so

equipped).

3. Remove the manifold locking device and slide the

burner and manifold assembly back towards the

furnace inlet until the burners are clear of the heat
exchanger tubes. See Fig. 5.

4. Slide manifold assembly towards the front of furnace .

until it clears the blower deck.
NOTE:

Keep manifold assembly straight while

removing. If manifold is cocked, then the assembly

will bind in burner box.

5. Place manifold on a work area and disconnect the

pilot tubing and thermocouple, if equipped, from the

valve

6. Using 2 pipe wrenches (one on the gas valve and

one on the manifold extension pipe), remove the

gas valve

7.

Remove the manifold extension pipe from the

manifold (it may be necessary to put a pipe wrench
on the manifold pipe while turning the extension).

8. Using 2 pipe wrenches (one on the manifold pipe

between the pipe cap and burner orifices and one on
the pipe cap), remove the pipe cap.

9. Clean the threads on manifold pipes, gas valve and

pipe cap of any old pipe dope.
NOTE: Use a joint compound (pipe dope) resistant
to the action of liquefied petroleum gases or to any
other chemical constituents of the gases to be
conducted through the piping.

10.

Using a suitable joint compound and 2 pipe

wrenches, replace the manifold pipe extension where
the pipe cap was. The pipe extension should be
tightened and positioned so that it is pointing
towards the back of the burners.

11. Using 2 pipe wrenches (one on the manifold exten­

sion and the other on the gas valve), tighten gas
valve to the extension and position the valve so that
the manual knob is in the 12 o’clock position

12. Using 2 pipe wrenches (one on the pipe cap and the

other on the manifold pipe), tighten the pipe cap to
the other end of the manifold pipe

13. Remove the screws holding the pilot bracket to the

crossovers of the first 2 burners When removing

pilot assembly, be carelul not to damage the pilot

gas tubing and ignition cable (or thermocouple, if so
equipped).

NOTE This step is not required foi 050 size, as
there are only 2 burners

Manulacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book|1 |4

PC 101

Catalog No 535-834

PrintedinUSA

Form 58ED,PB-1SI

Pgll

6-85

Replaces: 58PB-1SI

For replacement items use Carrier Specified Parts

Tab I6al8a

Advertising
This manual is related to the following products: