Carrier 580PB User Manual

Installation, start-up and service instructions, 58ed,pb horizontal gas-fired furnaces, Table 1 — physical data and dimensions

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

HEATING A COOLING

58ED,PB

Horizontal Gas-Fired Furnaces

Installation, Start-Up and Service Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS................................ 1
GENERAL ................................................................. 1

INSTALLATION .................................................... 2-13

Step 1 — Select Location ...........................................2
Step 2 — Provide Air For Combustion and

Ventilation.............................................................. 3

Step 3 — Assemble Furnace ......................................3

• DRAFT HOOD

Step 4 — Size Ductwork ........................................... 4
Step 5 — Vent Furnace ..............................................4

• MASONRY CHIMNEY
• TYPE B-1 VENT
• ATTIC INSTALLATION

Step 6 — Connect Gas Piping ................................... 5

• BURNER ORIFICES

Step

7

— Make Electrical Connections ..................... 6

Step 8 — Install Filters ............................................. II
Step 9 — Reverse Components

(if required) ........................................................ 11-13

START-UP AND ADJUSTMENT ........................13-15
SERVICE AND MAINTENANCE .......................15-17

SAFETY CONSIDERATIONS

These instructions are intended for use by qualified

personnel who have been trained in installing this type of
furnace. Installation of this furnace by an unqualified
person may lead to equipment damage and/or a
hazardous condition which may lead to personal injury

GENERAL

This furnace is designed for use with either natural or

liquefied petroleum (propane) gases and has been design
certified by the American Gas Association It is shipped
as a packaged unit, complete with burners and controls,
and requires only a line voltage ( 115-v) connection to the

Fig. 1 — Furnace Dimensions

(Modei 58ED Shown)

junction box and a thermostat hookup as shown in the
wiring diagram. The design of the furnace is such that
the burners, controls and flue outlet can be assembled
on the same side to facilitate servicing for installations
where only limited access to the unit is available. (See
Step 9 — Reverse Components.) The 58ED furnace

(with intermittent electronic ignition) is shown in Fig. I.
This furnace has been designed to interface with split-

system cooling equipment (approved by UL) to provide
year-round air conditioning. The blower is sized for
both heating and cooling. Table I provides physical
data and dimensions of the furnaces, and Table 2 pro­
vides airflow data.

The furnace installation must conform with local

building codes or, in the absence of local codes, with the
National Fuel Gas Code, NFPA54-I984/ANSI Z223.I-

I984 For complete information on installation standards

consult the National Fuel Gas Code, obtainable at a
nominal cost from the National Fire Protection Associa­
tion, Inc., Batterymarch Park, Quincy MA 02269 or the

Table 1 — Physical Data and Dimensions

SIZE 58ED/PB FURNACE

OSO

075

100

125

140

INPUT (1000 Btuh)*

50

75

100

125

140

HEATING CAPACITY (1000 Btuh)t

Non-Weatherized

38

56

75

94

105

Indoor

39

58

77

96

108

TEMPERATURE RISE (F)

35-65

40-70

40-70

40-70

40-70

DIMENSIONS (ft-ln.)

Length A

4-6

4-6

4-6

4-8

4-8

Width B

1-

V/2

1-

1-5

1- 8Уг

2-0

Duct Opening C

0-11 Ye

0-11 Ye

1-ЗУв

1- 6Ув

1-10Ув

Vent Diameter D

0-4

0-4

0-5

0-5

0-6

E

1- 8%

1- 8У4

1-8У4

1- 8У4

1- 7У4

F

0- 8%

0- 8%

0-6У8

0- 9У2

0- 9Уг

G

1-4

1-4

1-4

1- 5У4

1- 5У4

1- 9У4

1- 9'/4

1-9У4

1-11 '/4

1-11 '/4

1- 7%

1- 7У4

1-7У4

1- 5У4

1- 5'/4

NUMBER OF BURNERS

2

3

4

5

6

SHIPPING WEIGHT (lb)

155

165

190

230

250

‘Ratings shown are for elevations up to 2000 ft above sea level.

For elevations above 2000 ft, deduct 4% of input capacity for

each 1000 ft above sea level

fDetermined as per U S Government standard tests

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obiigations.

Book|1 |4

PC101

Catalog No 535-834

Printed in U S A

Form 58ED,PB-1SI

Pg 1

6-85

Replaces: 58PB-1 SI

For replacement items use Carrier Specified Parts.

Tab |6a|8a

Advertising
This manual is related to the following products: