A warning, Installation, 58ed,pb horizontal gas-fired furnaces – Carrier 580PB User Manual

Page 2: Installation step 1 — select location, Table 2 — blower data (direct drive)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

HEATING A COOLING

58ED,PB

Horizontal Gas-Fired Furnaces

American Gas Association, 1515 Wilson Boulevard,
Arlington, VA 22209.

A WARNING

The furnace cabinet must have an uninterrupted or
unbroken electrical ground to minimize personal

injury if an electrical fault should occur. The unit
must also be electrically grounded in accordance
with local codes, with the National Electrical Codes
ANSl/NFPA No. 70-1984 or the latest edition. Do
not use gas piping as an electrical ground.

INSTALLATION

Step 1 — Select Location

— This furnace may be

located in an attic, basement crawl space, alcove or
suspended from the ceiling of a utility room or basement.
As shown in Table 3, the minimum clearances, or greater,
must be provided between the furnace and adjacent
construction.

A WARNING

Failure to comply with all the recommended clear­

ances will result in a fire hazard.

If a furnace is to be installed in a residential garage, it

must be installed so the burners and the ignition source
are located not less than 18 in. above the floor and the
furnace must be located or protected to avoid physical
damage by vehicles.

The furnace should be located as close to the chimney

as possible in order to keep vent connections as short and
direct as possible. The furnace should also be located as
near to the center of the air distribution as possible, and
should be mounted level.

Since this furnace is suitable for attic installation, it

must not be installed directly on carpeting, tile or other
combustible material. Line contact is only permissible
between lines formed by the intersection of the furnace
top and two sides and the building joists, studs or
framing. See Fig. 2

A clearance of at least 30 in. should be provided at the

front of the furnace for combustion air and servicing.

For attic installations, the passageway and service area

adjacent to the furnace should have a floor installed.
The areas adjacent to the combustion air openings must
be covered with fireproof board or sheet metal extending
a minimum of 12 in. from the furnace. See Fig. 2.

If the furnace is to be installed in a crawl space, consult

local codes. Use of a concrete pad one to 2 in. thick is
recommended.

If the furnace is to be suspended from the ceiling, it is

necessary to use steel pipe straps around each end of the
furnace. These straps should be attached to the furnace
with sheet metal screws and bolted to the rafters. The
furnace may also be suspended by an angle iron frame
bolted to the rafters.

A WARNING

Do not place combustible material on or against

the draft hood.

A WARNING

The furnace is not watertight and is not designated
for outdoor installation.

Table 2 — Blower Data (Direct Drive)

FURNACE 58ED/PB

050

075

100

125

140

SERiES (15th Digit

A

B

c

A

B

c

A

B

c

C

D

B

c

of Model No.)

BLOWER SIZE (in)

DXW

10x4

10x4

10x6

10x6

10x6

10x6

10x8

10x8

10x8

12 X 9

12x9

12 X 12

12x12

MOTOR HP (PSC)

%

V

a

'/3

%

V

a

'/3

'4

V

a

'/3

'h

3/4

’/2

3/4

SPEED TAP

Lo

Hi

Lo

Hi

Lo

Lo

Hi

Med

Hi

Med

Lo

Hi

Med

Hi

Med

Hi

Med

Hi

Med

Hi

Med

Hi

Med

WIRE COLOR

Red

BIk

Red

BIk

Red

Red

BIk

Blu

BIk

Blu

Red

BIk

Blu

BIk

Blu

BIk

Blu

BIk

Blu

BIk

Blu

BIk

Blu

BLOWER RPM

830

1070

760

1080

700

920

1020

790

1060

820

860

990

730

1050

840

1070

820

1000

920

1070

970

980

780

EXTERNAL STATIC

PRESSURE (in wg)

20

50

20

50

20

20

50

20

50

20

20

50

20

50

20

50

20

50

20

50

20

50

20

AIRFLOW (Cfm)

765

930

735

1220

790

1165

1130

995

1260

1090

1310

1290

1090

1530

1360

2010

I860

2115

1810

2100

1930

2350

2100

A WARNING

When operating furnace in heating mode, the static pressure
and the temperature rise (outlet air temperature minus room
temperature) must be within those limits specified on the
AGA rating plate.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without Incurring obligations.

Book|1 |4

PC101

Catalog No 535-834

Printed in U S A

Form 58ED.PB-1 SI

Pg 2

6-85

Replaces: 58PB-1 SI

For replacement Items use Carrier Specified Parts

Tab I6al8a

Advertising
This manual is related to the following products: