Installation Instructions (continued)

PREPARATION

• Remove di tape and packaging. Lift up the cooktop

(on models with standard twin burners) and remove

any packing material under it. Make sure the
standard twin burners are properly seated and level.

• Remove plastic film that covers some chrome parts

(around oven door, side trim).

• Take the accessory pack out of the oven.

• Check to be sure that no range parts have come loose

during shipping.

STEP I

Provide Adequate Gas Supply

Your ranee is designed to operate at a pressure of T'

(iO.2 cm) of water column on natural gas or, if designed

for LP gas (propane or butane), 10" (25.4 cm) of water
column. Make sure you are supplying your range with
the type of gas for which it is designed. This range is
convertible for use on natural or propane gas. If you
decide to use this range on LP gas, conversion must be

made by a qualified LP installer before attempting to

operate the range on that gas.

For proper operation, the pressure of natural gas
supplied to the regulator must be between 4" (10.2 cm)
and 13" (33 cm) of water column. For LP gas, the
pressure supplied must be between 10" (25.4 cm) and

13" (33 cm) of water column. When checking for

proper operation of the regulator, the inlet pressure must
be at least 1" (2.5 cm) greater than the operating

(manifold) pressure as given above. The pressure
regulator located at the inlet of the range manifold must
remain in the supply Une regardless of whether natural
or LP gas is being used. A flexible metal appliance
connector used to connect the range to the gas supply
line should have an LD. of 1/2" and be 5 feet (1.5 m)
in leng th for ease of installation. In Canada, flexible
connectors must be single wall metal connectors no
longer than 6 feet (1.8 m) in length.

I in« 1

Connect the Range to Gas

Shut off the main gas supply valve before disconneedng
the old range and leave it off until new hook-up has
been completed. Dont forget to relight the pilot on
other gas appliances when you turn the gas back on.

Because hard piping restricts movement of the range,
the use of an A.G A.-certified flexible metal appliance
connector is recommended unless local codes require a
hard-piped connection. Never use an old connector
when installing a new range. If the hard piping
method is used, you must carefidly align the pipe; the
range cannot be moved after the connection is made.

To prevent gas lealcs, put pipe joint compound on, or
wrap pipe thread tape with Teflon* around, all male

(external) pipe threads.

'Teflon- Registered ttadcmaffc of DuPont

Gas Ripe and Electric Outlet Locations
for Models Equipped with Sealed Burnere

This area allows

for flush range
instailation with

through-the-wall

connection of pipe
stub/shut-off
valve and rear
wall 120V outlet

Shortest
connection

from hard pipe

stub location to
range hookup.

This area allows for
flush range installation
with through-the-ffoor
connection of pipe
stub/shut-off valve

36

Advertising