1.

Turn hand wheel toward you to raise

needle to its highest position,

2,

Open slide plate, remove needle plate

and remove bobbin,

3. I nsert screwdriver Into bobbin case hold

down and turn it toward the rear as il­
lustrated.

4, To remove bobbin case:

® Push bobbin case toward the rear and

lift It up and out toward the front.

5, To replace bobbin case:

® Oiulde forked Bn6ur\6Qr the

® Draw bobbin case toward you so that

front of case Is under the position
plate as Illustrated.

« Turn bobbin case hold down toward

you to lock bobbin case In position.

6. Replace bobbin, needle plate and dose

slide plate.

Sobbin
Case

Holder

Position Plate

Raise presser foot and make sure needle

is In its highest position.

Place slide plate In slideway with front
edge close to but not covering the retain­
ing spring as shown.

With a small screwdriver, lift ends of
spring Into the slide grooves on under­
side of plate.

Draw plate gently toward you to fully
engage the spring.

Open S;

under

lift

it

right.

plate; place thumb

side of needle plate,

and withdraw

it to

R e p l a c e

needle

plate

under

clamping pin, push it gently to
the left, and press down until It
snaps Into place. Close slide

ing Spring into