Dismantling the cutting unit

The cutting unit can be released from the machine
for cleaning or checking of the blades and screws.

Dismantle the cutting unit as follows:

1. Dismantle the front hood as described on page

18.

2. Dismantle the pull-rod (1). A tool can be used

when the needle spring is removed to carefully
bend out the pull-rod from its holder.

3. Relieve the tensioning pulley (2) by disconnect­

ing the spring (3).

4. Fold the lock plate (5) forwards and press down

the front edge of the unit so that it releases from
the unit frame (4).

5. Push the unit backwards and dismantle the drive

belt, and then pull the unit forwards so that the
back end releases from the unit frame.

Fitting of the cutting unit takes place in the reverse

order to dismantling.

WARNING!
Wear protective glasses when dis­
mantling the cutting unit. The spring

which tensions up the belt can go
off and cause personal injury.

Checking the blades

To achieve the best mowing results it is important

that the blades are undamaged and well-

sharpened.

Check that the blades’ attachment screws are tight,

(45-60 Nm, 33-44 Ib.ft)

IMPORTANT INFORMATION

Replacing or sharpening the blades
should be conducted by an authorised

service workshop.

IMPORTANT INFORMATION

The Bioclip unit should always have the

blades in the relative positions shown in

the diagram, with a 90° angle between the

blades. Otherwise the biades can go
against each other and cause serious
damage to the unit.