Quietpact™ 75d recreational vehicle generator – Generac Power Systems 4270-0 User Manual

Page 8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

GENERAL

INFORMATION

Section 1 - Generai Information

QUIETPACT™ 75D Recreational Vehicle Generator

♦ 1.5.2 FUEL CONSUMPTION (GAl/HR)

Modd

No Load

Half Load ЕШ Load

QUTETPACT™ 75D
(04270-0)

0.28

0.45

0.78

♦ 1.5.3 ENGINE OIL REQUIREMENTS_______________

Use

a

high-quality

detergent

oil

with

American

Petroleum Institute (API) classification ‘‘For Service
CC.” Detergent oils keep the engine cleaner and reduce
carbon deposits. Use oil having the following SAE vis­
cosity rating, based on the amMent temperature range
anticipated before the next oil change:

Temperature

Oil Grade (Recommended)

Above 100° F (38° C)

SAE 15W-40 or SAE 40

40° to 100° F (4.4° to 38° C)

SAE 10W-30 or SAE 30

Below 40° F (4.4° C)

SAE 5W-20 or 5W-30

Crankcase and oil filter capacity is approximately 3.5
L or 3.7 U.S. quarts. Do NOT use special additives.
See Sections 3.1 and 3.2 (Page 12) for oil level check­
ing and changing procedures.

♦ 1.5.4 COOLANT____________________ _________ __

Use a mixture of half low silicate, ethylene glycol base
antifreeze and half soft water. Use only soft water and
only low silicate antifreeze. If desired, you may add a
high

quality

rust

inhibitor

to

the

recommended

coolant mixture. When adding coolant, always add
the recommended 50-50 mixture.

A

A

DANGER

Do not remove the radiator pressure cap while

the engine is hot or serious burns from boiling

liquid or steam could result.

Ethylene glycol base antifreeze is poisonous. Do
not use your mouth to siphon coolant from the
radiator, recovery bottle or any container. Wash
your hands thoroughly after handling. Never store
used antifreeze in an open container because ani­
mals

are

attracted to the smell and taste of

antifreeze even though it is poisonous to them.

---------

Ik

CAUTION ------------------------ -

Do not use any chromate base rust inhibitor with
ethylene glycol base antifreeze, or chromium
hydroxide ("green slime") will form and cause
overheating. Engines that have been operated
with a chromate base rust inhibitor must be
chemically cleaned before adding ethylene glycol
base antifreeze. Using any high silicate antifreeze
boosters or additives also will cause overheating.
We also recommend that you DO NOT use any
soluble oil inhibitor for this equipment.

Generac* Power System s, Inc.

♦ 1.5.5 ENGINE_________________________________

туре of Engtae................................................................ ISM Diesel

Cylinder Arrangement ...................................................... 3, in-line
Displacement........................................................ 58.2 in. (954 cc)
Bore........................................................................ 2.95 in. (75 mm)
Stroke..................................................................... 2.83 in. (72 mm)
Compression Ratio................................................................ 23-to-l
Combustion Chamber Type................................ Pre-Combustion

Rated Horsepower...............................................13 @ 1,950 rpm
Cylinder Block...................................................................Cast Iron
Number of Main Bearings..............................................................4
Number of Tteeth on Flywheel.................................................. 104
Type of Governor .................................. Mechanical, Fixed Speed
Fhel Filter...............................FbU Flow Spln-On (Part # 69858)

Oil Filter............................................ Pull Flow with Bypass Valve

(Part # 126-70939)

Oil Pressure....................................................................... 29-71 psl
туре of Cooling System................. Pressurized, Closed Recovery
Cooling Method......................................................... Liquid-cooled
туре of Cooling Fhn ........................................... Centrifu^ Puller
Cooling System Capaclly .............................. 1.4 U.S. gals (5.3 L)
Air Cleaner...............................Disposable Filter (Part # C4880)

Starter............................................................... 12-volt DC Electric
Recommended Battery........................70 Ah, 360 Cold-cranking

Amps

Maximum Cranking Current......................................... 220 Amps
Ground Polarity..................... ............................................. Negative

♦ 1.5.6 GENERATOR

Rated Maximum Continuous AC Output at...

85° F (29° C) Ambient.............................. 7,500 Watts (7.5 kW)

100° F (38° C) Ambient ..........................7,000 Watts (7.0 kW)
120° F (49° C) Ambient ..........................6,000 Watts (6.0 kW)

Rated Voltage.................................................... 120/240 Volts AC*
Rated Maximum Continuous AC Current at...

7,500 Watts

120 Volts............................................................. 62.5 Amps

240 Volts............................................................. 31.2 Amps

7.000 Watts

120 Volts............................................................. 58.3 Amps

240 Volts............................................................. 29.2 Amps

6.000 Watts

120 Volts........................................ .....................50.0 Amps

240 Volts............................................................. 25.0 Amps

Phase..................................................................................... Single
Rotor Speed at No Load ......................... ......................3,780 rpm
Number of Rotor Poles................................................................. 2
Engine RPM........................................................................ 1,950
Rated AC Frequency ................. ........................................... 60

Hz

Batteiy Charge Voltage................................................ 14 Volts DC
Battery Charge Current........................................... 2 Amps (max)
Weight........................................................................... 486 Pounds
Length......................................................... 36.6 inches (929 mm|
Width................................................... ....... 23.8 Inches (604 mm)
Height..........................................................22.3 Inches (567 mm)

*A11 units are reconnectable to 120-volt-only AC output.

Advertising