Section 2 - Operation

QUIETPACT™ 75D Recreational Vehicle Generator

OPERATION

(Jti

2.1

GENERATOR CONTROL PANEL

The following features are mounted on the generator

control panel (Figure 2.1):

Figure 2.1 - Generator

Control

Panel

♦ 2.1.4 LINE BREAKER

UNE
BREAKER

FUSE

PREHEAT

♦ 2.1.1 HOURMETER

This

indicates

the

time

the

engine-generator

has

operated,

in

hours

and

tenths

of

hours.

Use

the hourmeter to ensure that the periodic mainte­
nance tasks for your generator are completed on a
timely basis.

♦ 2.1.2 START/STOP SWITCH

To crank and start the engine, hold this switch in the

START position. Release the switch when the engine
starts. To stop an operating engine, press emd hold
the switch in the STOP position until the engine shuts
off. The switch center position is the RUN position.

♦ 2.1.3 FUSE

The 14 amp fuse protects the engine’s DC control cir­

cuit against electrical overload. If the fuse element
has melted open due to overloading, the engine can­
not be cranked. If you must replace the fuse, use only
an identical replacement (SFE-14).

A

-------- ik CAUTION ik-------------------

If a fuse element melts, you should find the
cause of the overload before replacing the fuse.

The line (main) breaker protects the generator’s AC

output

circuit

against

overload

and

provides

a

method of turning OFF the generator’s 120/240-volt

AC output to the vehicle circuits. The QUIETPACT™

75D has two 35-amp breakers.

NOTE:

Refer to Section 1.4, “Generator AC Connection
System,” (Page 5). Individual installations will

differ. If an overload occurs, the dual breakers

will open the ungrounded(hot) stator leads (11

and 44).

When

the generator has been connected

for 120 volts only, the line breakers will operate
independently

on

the

ungrounded

(hot)

stator

leads (11 and 33).

♦ 2.1.5 PREHEAT SWITCH_______________________

The diesel engine is equipped with glow plugs, one
for

each

cylinder.

When

you

press

the

preheat

switch, the glow plugs heat the engine combustion
chamber

for

quicker

starts

when

the

engine

is

cold. Pressing the preheat switch also operates the
fuel pump.

2.2

OPTIONAL REMOTE START/STOP

This generator is equipped with a plug-in connector
which can be interfaced with an optional remote
panel provided inside the vehicle. This option allows

you to start and stop the generator conveniently from
within the vehicle. Refer to Part II - Installation

Instructions, Section 2.8 for details on the remote
start/stop option.

23 BEFORE STARTING THE ENGINE

NOTE:

Instructions

and

information

in

this

manual

assume

the

generator

has

been

properly

installed,

connected,

serviced,

tested

and

adjusted by a qualified installation technician or
installation contractor.

2.3.1

INSTALLATION___________________________

Generator

installation

must

have

been

properly

completed so it complies with all applicable codes,
standards

and

regulations

and

with

the

manufac­

turer's recommendations.

Generac* Power Systems, Inc.