GENERAL INSTALLATION INFORMATION

PURPOSE AND SCOPE OF MANUAL

These

Installation

Instructions

have

been

prepared

especially for the purpose of familiarizing installers
and owners of the applicable equipment with the pro­
duct's installation requirements. Give serious consid­
eration to all information and instructions in the manu­
al, both for safety and for continued reliable operation
of the equipment.

Because of the different recreational vehicle models
and the variations between the models, it would be
extremely

difficult,

if

not

impractical,

to

provide

detailed instructions on every installation possibility.

For that reason, instructions and illustrations in this
manual are general in nature. Illustrations are not
intended to serve as detailed installation blueprints.

The installation should comply strictly with all applica­

ble codes, standards and regulations pertaining to the
installation and use of this product. If any portion of

this manual appears to be in conflict with such codes,
standards or regulations, the applicable codes, stan­
dards,or regulations must take precedence over the

manual.

SAFETY

Before handling, installing, operating or servicing this

equipment, be sure to read carefully the “Notice to

Installer” and “Safety Rules” at front of this manual.

Comply with all SAFETY RULES to prevent death,
personal injury or damage to equipment and/or prop­
erty. Stress safety to all installers, operators and ser­
vice technicians who work on this equipment.

STANDARDS BOOKLETS

Installation,

use

and

servicing

of

this

equipment

should comply strictly with published standards, as
well as the manufacturer's recommendations. The fol­
lowing standards booklets (latest revision) are avail­
able from the sources indicated:

1.

NFPA Standard 501C, “Standard for Recreational

Vehicles”, available from the National Fire Protection
Association, Batterymarch Park, Quincy, MA 02269.

2. NFPA 70, “NFPA Handbook of the National Electric

Code”, obtained from same address as Item 1.

3. ANSI Cl-1975 and ANSI 119.2-1975, available from the

American National Standards Institute, 1430 Broadway,

New York, NY 10018.

4.

ANSI

A119.2/NFPA

501C,

available

from

the

Recreational Vehicle Association, 1896 Preston White
Drive, Reston, VA 22090.

5. California Administrative Code, Title 25, available from

the State of California, Documents Section, P.O. Box

1015, North Highlands, CA 95660.

6. CSA Electrical Bulletin 946, available from the Canadian

Standards

Association,

Housing

and

Constructions

Materials Section, 178 Rexdale Boulevard, Rexdale,

Ontario, Canada, M9W 1R3.

EQUIPMENT DESCRIPTION

Instructions and information in this section pertain to

Generac air-cooled generators. These generators are
designed specifically for installing in recreational vehi­
cles. They operate 120 volt, single phase, 60 Hertz, AC
electrical loads that require 46.0 amps at 120 volts.

ENGINE GENERATOR

OPERATING SPEED

The generator’s revolving field (rotor) is driven by a
single-cylinder, 4-cycle engine through a pulley and
drive belt arrangement. The generator supplies 120
volts AC at 60 Hertz when the rotor is operating at
3600

rpm.The

drive

belt

arrangement

allows

the

engine to operate at a lower speed than the rotor.

GENERATOR AC CONNECTION

SYSTEM

The generator is equipped with dual stator power
windings as shown in figure 13.

Figure 13 — 120 Volt Single Voltage Connection

OROUNDED

NEUTRAL

• The AC connection system on all air-cooled QP series

generators uses a GROUNDED neutral.

• A separate green ground wire is connected to the recre­

ational vehicle’s junction box.

• For these QP55 units, loads connected across T1 (red) to

T2 (white), MUST NOT exceed 30 amperes or 3600 watts

and loads connected across T3 (black) and T2 (white)

MUST NOT exceed 20 amperes or 2400 watts each at

120 volts. The combined loading of the two breakers

should not exceed 5500 watts.

IMPORTANT: DO NOT CONNECT LOADS IN EXCESS OF
CIRCUIT BREAKER RATINGS.