LOCATION AND SUPPORT

GENERATOR LOCATION

The most desirable location for the generator set is

between the vehicle's main frame members However,

this is seldom possible. Most ünits must be installed

on the side of the vehicle and are difficult to reinforce.
Many

recreational

vehicles have

been

factory

equipped with an area for the generator set. Some
vehicles may even have a generator compartment,
provided by the vehicle manufacturer.

Plan the generator location based on the following;

• The generator set must be installed on a framework that

is part of the recreational vehicle, as outlined in the para­
graph entitled “Generator Support.”

• The location must provide an access opening that is large

enough to permit generator removal (unless the genera­
tor is to be removed from underneath the supporting

framework).

• The location must provide easy access to frequently ser­

viced components, such as filters,, oil drains, spark plugs
and other common maintenance parts.

• The location must provide sufficient room to allow mini­

mum

clearances

as

outlined

in

the

“Generator

Compartments” section. If sound insulation is to be used
on compartment walls and ceiling, the minimum recom-

. mended applies to the space between the generator and

such insulation.

• The location must provide adequate cooling and ventilat­

ing air flow for the generator without a great deal of work
and expense.

GENERATOR SUPPORT

The generator must be securely attached to a metal
framework that has been made part of the vehicle
frame structure by bolting or welding; The metal
framework on which the generator will rest and which
will restrain the generator set should consist of at

least two horizontal beams. These beams should con­
sist of (a) 1-1/2 inch square,. li gauge steel tubing

OR (b) 1-1/2 inch, 11 gauge angle iron. A typical sup­
porting frame with horizontal support tubing, is shown

in Figure 14.

The generator can be instalied so that it sits on top oT
the horizontal support tubing, if the vehicle design
permits. Another method is to suspend thé generator
below the horizontal support tubing by means of suit­

able, structurally sound metal framework. The follow­
ing general rules apply;

• Vehicle construction MUST be capable of supporting the

weight of the generator.

• Whether the generator is mounted above the horizontal

support tubing or suspended below the tubing, the sup­

porting frame used must be structurally sound.

• If the generator cannot be bolted directly to the support­

ing frame or support tubing, consider using additional

tubing, angle brackets or other supports to give the sup­

porting frame sufficient strength.

Figure 14 — Typical Horizontal Support Frame

SUSPENDED MOUNTING

The location of a suspended mounting system must

be carefully planned, keeping the following general
rules in mind;

• Protect the generator against road splash and debris.

Baffles or splash guards may be required to protect cer­

tain areas of the generator. To make sure the generator is

adequately protected, road test the installation through

mud, water and slush.

• The installer must make certain that selected location will

permit adequate cooling and ventilating air flow to be

supplied.

Supplied with your generator are two brackets that
may be used for the suspended system as shown in
Figure 15. Use the provided bolts and washers to
attach the brackets to the genset.

Figure 15 — Typical Suspended Mounting System

IMPORTANT; If supplied brackets are used for sus­

pended mounting, four 3/8”-16 bolts, lockwashers and

flatwashers must be tightened in the generator
mounting holes.

— 1 5 —