Hidden Features

Program Customization

The Pro-C is factory configured with 3 independent programs
(

A, B, C with four start times each) for different plant type

requirements. The Pro-C can be customized to display only the
required programs. You can hide those programs that are not
required to ease programming.

1. Start with the dial in the

RUN position.

2. Press and hold the k button. Turn the dial to the

WATER

DAYS position.

3. Release the k buttons.

4. Use the j and k button to change program modes.

Programmable Delay Between Stations

This feature allows the user to insert a delay between when
one station turns off and the next station turns on. This is
very helpful on systems with slow closing valves or on pump
systems that are operating near maximum flow or have slow
well recovery.

1. Start with the dial in the

RUN position.

2. Press and hold the k button while turning the dial to the

RUN TIMES position.

3. Release the k button. The display

will show a delay time for all
stations in seconds.

4. Press the j and k buttons

to increase or decrease the delay time between 0 and 59
seconds in 1 second increments and then in one minute
increments up to four hours.

Hr will be displayed when the

delay changes from seconds to minutes and hours. Maximum
delay is 4 hours.

5. Return the dial to the

RUN position.

NOTE

The Master Valve/Pump Start circuit will operate during the first
15 seconds of any programmed delay to aid in the closing of the
valve and to avoid unnecessary cycling of the pump.