Connecting AC Power

Indoor Cabinet

Route transformer cable through the hole on the bottom left
side of the controller and connect one

Yellow Wire to each of the

screws marked

AC and the Green Wire to GND.

NOTE

To be performed by a licensed electrician only.

Always use UL listed ½" (13 mm) conduit with male adapter
when installing AC wiring. Pro-C/PCC controllers are intended
to be supplied AC power with a 15A rated overcurrent
protected device.

Outdoor Cabinet

1. Route

AC power cable and conduit through the ½" (13 mm)

conduit opening on the left side of the bottom of the cabinet.

2. Connect the wires to the transformer wires located inside the

junction box. International units are supplied with a built in
terminal strip. Always use a UL listed conduit ½" (13 mm) male
adapter when installing the

AC wiring.

3. Insert the adapter into the ½" (13 mm) hole at the bottom of the

controller. Attach a nut to the adapter inside the enclosure.

4. Connect a 9-volt

alkaline battery (not included) to the battery

terminals and place in the battery compartment in the front
panel. The battery allows the user to program the controller
without AC power.

Watering will not occur without AC power.

Since this controller has non-volatile memory, the program
clock and calendar will be retained during a power outage even
if no battery is installed.

Connecting AC Power

GND

(Green)

AC1

(Yellow)

AC2

(Yellow)

120 V

230 V

U.S.A.

INTERNATIONAL

Outdoor Cabinet

GROUND

(Green)

NEUTRAL

(White)

HOT

(Black)

Indoor Cabinet

Advertising