Check the function and indication of auto-mode
a.
Set A-M switch to A-side.
b.
Checking process is the same as ME mentioned before.
Check the function and indication of manual-mode
a.
Set A-M switch to M-side.
b.
Set UP-DOWN switch OFF position.
c.
Confirm LED movement.
*LED should moves up and/or down to the direction which fixed by UP-DOWN
switch.
Check the indication of EF
Red LED at the top should be flickering when set EF switch ON.
4.
Check 23901 and 23904 P.C. board pattern
a.
Install the adapter for MV to the connector.
b.
Set ME-MV switch to MV side.
c.
Insert P.C. board pattern to the connector of adapter.
d.
Checking process is the same as ME. But the application range of VR is
opposite.