Page 6 of 32

2) LED positioning

Use P.C. board pattern checker (239 PATTERN CHECKER). Adjust LED

position by sliding the LED supporting plate.

Each LED should be aligned with its figure in the view-finder.

3) As installing Photo-cell part to Cell frame (N1), insert P.C. board to

the connector.

4) Photo-cell part

Hot shoe contact piece C (N9)
T-CNL-E 1.7 x 3
Insulation plate (Nl3)
Insulation collar (N8)
Hot shoe contact piece A (N4)
T-CNL-E 1.7 x 4

8.

Front board and Mirror housing

Shutter block

charged condition

Mirror housing

released condition

*lAThen installed, take care about lead wires.

Front board retainer screw (A132-01) 4pcs.
W14
P. C. board retainer (I1)
CNL-Dl.7 x 3 x 2

After installed, check the functions of shutter.

9.

Mechanical back focus.

45,46 ± 0.04mm

10. Soldering

The location of solder

refer to page 1 and 2.

Especially, red and blue lead wire should be positioned

between Relay P.C. board assy. (0-A129) and Prism seat

assy. (0-M2), as shown left. — to prevent from catching

between the top cover and the prism seat.

11. ASA volume (R100)

ASA volume retainer scerw (A16-01)
CNL-D 1.7 x 2. 5

12. Bottom cover assy. (A400)

Connector seat (A23)
Bottom cover assy. (A400)
CSS 1.7 x 3 x 2

CSS 1.7 x 2.2

13. Load the batteries

G13 x 2