Pentax me super User Manual

Page 8

Advertising
background image

23903

Page 7 of 32

14.

Confirm the function of LED of P.C. board pattern and/or LED positioning

*If P.C. board pattern checker is not ready, adjust LED position at

this time.

Confirm the function of LED as follows.

1) After the main switch was ON, LED stays on about 30 sec..

2) LED indicates as Manual-mode at when the top cover does not install.

3) LED should be changed the indication when connect the points as

mentioned below.

a.

A — D

Auto-mode CBA D =ground

b.

B — D

Manual-mode
LED keeps down

c.

C — D

Manual-mode
LED keeps up

15.

Install ASA ring assy. (0-D11-01) temporary.

When set ASA ring out of 1X, red LED of EE should be flickering.

16.

Install the temporary top cover.

17.

Adjust the auto shutter-speed and the LED indication.

1) Auto shutter-speed

EV12

Light value correction unit

ASA100 1X
f8 — using f8 set ring

KA-00- 1A

2.8V

Regulated D. C. power

supply

Shutter dial AUTO

*Nominal speed

15.6 ms

Adjust by VR1. After adjusted, check other EVs. (EV16 1X, EV16 1/2X,

EV8)

Standard of shutter speed is the same as 23900.

*Standard of 1/2000sec.

0.49±0.7EV ms.

(0.30

0.81 ms.)

2)

LED indication
EV12
ASA 100 lX
f8
2.8V
Shutter dial AUTO

LED of 60 should be turned on at the above combinations.

Adjust by VR2. LED of 60 should not move to next LED when

changed ASA from 80 to 125.

After adjusted, check other EVs.

Advertising